mirror of
https://github.com/freebsd/freebsd-src.git
synced 2024-11-30 10:52:50 +00:00
[PowerPC] Allow traversal of oversize OF properties.
In standards such as LoPAPR, property names in excess of the usual 31 characters exist. This breaks property traversal. While in IEEE 1275-1994, nextprop is defined explicitly to work with a 32-byte region of memory, using a larger buffer should be fine. There is actually no way to pass a buffer length to the nextprop call in the OF client interface, so SLOF actually just blindly overflows the buffer. So we have to defensively make the buffer larger, to avoid memory corruption when reading out long properties on live OF systems. Note also that on real-mode OF, things are pretty tight because we are allocating against a static bounce buffer in low memory, so we can't just use a huge buffer to work around this without it being wasteful of our limited amount of 32-bit physical memory. This allows a patched ofwdump to operate properly on SLOF (i.e. pseries) systems, as well as any other PowerPC systems with overlength properties. Reviewed by: jhibbits MFC after: 2 weeks Sponsored by: Tag1 Consulting, Inc. Differential Revision: https://reviews.freebsd.org/D26669
This commit is contained in:
parent
1740c2dbb6
commit
26869ad14c
Notes:
svn2git
2020-12-20 02:59:44 +00:00
svn path=/head/; revision=367643
@ -115,7 +115,7 @@ openfirm_ioctl(struct cdev *dev, u_long cmd, caddr_t data, int flags,
|
||||
phandle_t node;
|
||||
int len, ok, error;
|
||||
char *name, *value;
|
||||
char newname[32];
|
||||
char newname[OFIOCSUGGPROPNAMELEN];
|
||||
|
||||
if ((flags & FREAD) == 0)
|
||||
return (EBADF);
|
||||
@ -222,8 +222,19 @@ openfirm_ioctl(struct cdev *dev, u_long cmd, caddr_t data, int flags,
|
||||
break;
|
||||
}
|
||||
len = strlen(newname) + 1;
|
||||
if (len > of->of_buflen)
|
||||
if (len > of->of_buflen) {
|
||||
/*
|
||||
* Passed buffer was insufficient.
|
||||
*
|
||||
* Instead of returning an error here, truncate the
|
||||
* property name to fit the buffer.
|
||||
*
|
||||
* This allows us to retain compatibility with old
|
||||
* tools which always pass a 32 character buffer.
|
||||
*/
|
||||
len = of->of_buflen;
|
||||
newname[len - 1] = '\0';
|
||||
}
|
||||
else
|
||||
of->of_buflen = len;
|
||||
error = copyout(newname, of->of_buf, len);
|
||||
|
@ -76,4 +76,18 @@ struct ofiocdesc {
|
||||
/* Maximum accepted value length (maximum of nvramrc property). */
|
||||
#define OFIOCMAXVALUE 8192
|
||||
|
||||
/*
|
||||
* While IEEE 1275-1994 states in 3.2.2.1.1 that property names are 1-31
|
||||
* printable characters, in practice, this limit has been ignored.
|
||||
* Noncompliant properties have been codified in standards such as LoPAPR.
|
||||
*
|
||||
* This is a suggested buffer length that should be large enough to hold
|
||||
* any property name currently seen in device trees, without being overly
|
||||
* wasteful of memory.
|
||||
*
|
||||
* If a future version of the Devicetree specification updates the property
|
||||
* names length requirement, this value will be updated to match.
|
||||
*/
|
||||
#define OFIOCSUGGPROPNAMELEN 64
|
||||
|
||||
#endif /* _DEV_OFW_OPENFIRMIO_H_ */
|
||||
|
@ -144,7 +144,7 @@ static void
|
||||
ofw_dump_properties(int fd, phandle_t n, int level, int raw, int str)
|
||||
{
|
||||
int nlen;
|
||||
char prop[32];
|
||||
char prop[OFIOCSUGGPROPNAMELEN];
|
||||
|
||||
for (nlen = ofw_firstprop(fd, n, prop, sizeof(prop)); nlen != 0;
|
||||
nlen = ofw_nextprop(fd, n, prop, prop, sizeof(prop)))
|
||||
|
Loading…
Reference in New Issue
Block a user