The kernel source contains several definitions of an ilog2 function;
some are slower than necessary, and one of them is incorrect.
Elimininate them all and define an ilog2 macro in libkern to replace
them, in a way that is fast, correct for all argument types, and, in a
GENERIC kernel, includes a check for an invalid zero parameter.
Folks at Microsoft have verified that having a correct ilog2
definition for their MANA driver doesn't break it.
Reviewed by: alc, markj, mhorne (older version), jhibbits (older version)
Differential Revision: https://reviews.freebsd.org/D45170
Differential Revision: https://reviews.freebsd.org/D45235
Apply the following automated changes to try to eliminate
no-longer-needed sys/cdefs.h includes as well as now-empty
blank lines in a row.
Remove /^#if.*\n#endif.*\n#include\s+<sys/cdefs.h>.*\n/
Remove /\n+#include\s+<sys/cdefs.h>.*\n+#if.*\n#endif.*\n+/
Remove /\n+#if.*\n#endif.*\n+/
Remove /^#if.*\n#endif.*\n/
Remove /\n+#include\s+<sys/cdefs.h>\n#include\s+<sys/types.h>/
Remove /\n+#include\s+<sys/cdefs.h>\n#include\s+<sys/param.h>/
Remove /\n+#include\s+<sys/cdefs.h>\n#include\s+<sys/capsicum.h>/
Sponsored by: Netflix
In rS360398, a new iflib device method was added with default of opt out
for VLAN events needing an interface reset.
This re-init is unintentional for enetc(4).
MFC after: 2 weeks
Sponsored by: BBOX.io
Differential Revision: https://reviews.freebsd.org/D41558
Since d49e83eac3, iflib(9) is ready
for this change.
While at it, make isc_driver_version strings (static) const where
not apparently un-const on purpose, too.
This reduces the size of the amd64 GENERIC by about 10 KiB.
The SPDX folks have obsoleted the BSD-2-Clause-FreeBSD identifier. Catch
up to that fact and revert to their recommended match of BSD-2-Clause.
Discussed with: pfg
MFC After: 3 days
Sponsored by: Netflix
According to the RM it's not safe to disable a TX ring while it is busy
transmitting frames.
In order to be safe wait until the ring is empty. (cidx==pidx)
Use this opportunity to remove a set-but-unused variable.
Obtained from: Semihalf
Sponsored by: Alstom Group
According to the RM rings can hold at most ring_size - 1 descriptors at any time.
No additional logic is needed since iflib already respects this constrain.
Thanks to that the pidx == cidx situation is not ambiguous and indicates an
empty ring.
Use that to simplify the logic that calculates the amount of processed frames.
Obtained from: Semihalf
Sponsored by: Alstom Group
The NIC can IP align received packets.
It was observed that it caused some rare stalls, that required full board reset.
Disable this feature for now. It doesn't provide any significant performance
improvement anyway.
Obtained from: Semihalf
Sponsored by: Alstom Group
In theory we can have multiple concurrent accesses to the MDIO bus,
e.g. link status check tick and ifconfig request.
In that case we need to make sure that all MDIO transaction are
serialized.
Obtained from: Semihalf
Sponsored by: Alstom Group
The hash is calculated by XOR-ing together bits of the VID.
Prepend a statement with "!!" to make sure that we're get bit 0
on both sides of the equation.
Obtained from: Semihalf
Sponsored by: Alstom Group
It was previously used by felix(4) for PHY communication.
Since that is not the case anymore this driver is now left unused.
Obtained from: Semihalf
Sponsored by: Alstom Group
Use correct devclass name, due to the mismatch miibus would attach
to the wrong thing causing mii_attach to silently fail.
Fixes: dfcaa2c18b (enetc_mdio: Support building the driver ...)
The toolchain can reorder symbols, meaning that changing
the order of DRIVER_MODULE macros is not enough
to ensure that miibus gets registered first.
Use DRIVER_MODULE_ORDERED instead to fix the problem properly.
Fixes: 5ad6d28cbe ("enetc: Support building the driver as a loadable module.")
Reported by: jhb
After recent arm64 GENERIC config cleanup the ENETC MDIO
in NXP LS1028A SoC should support being loaded as a module.
Obtained from: Semihalf
Sponsored by: Alstom Group
Function level reset has to be done in attach in order to put the
hardware in a known state before configuring it.
The order of DRIVER_MODULEs was changed to ensure that the miibus driver
is loaded when mii_attach is called.
Obtained from: Semihalf
Sponsored by: Alstom Group
With the v5.13 device-tree update speed of the CPU switch port was
changed to 2.5G. Reflect that in the driver.
Submitted by: Kornel Duleba <mindal@semihalf.com>
Obtained from: Semihalf
Sponsored by: Alstom Group
Implement support for the NXP LS1028A SoC MDIO controller.
It is attached to the internal PCI root complex.
The controller is used to communicate with PHYs of ports connected
to the internal switch.
Submitted by: Lukasz Hajec <lha@semihalf.com>
Reviewed by: manu
Obtained from: Semihalf
Sponsored by: Alstom Group
Differential Revision: https://reviews.freebsd.org/D30731
ENETC it a gigabit Ethernet controller found on the LS1028A board.
It supports basic VLAN offloads - tag extraction, injection and hardware
filtering. Inband MDIO connectivity is used for link status
monitoring through the miibus interface. Fixed-link mode is also
supported, which allows for operation of internal cpu to switch port.
Since no admin interrupts are present in hardware, link status polling
has to be used.
Due to a hardware bug software reset of the NIC results in a external
abort. Because of that most of the hardware initialization is done
during attach. This also means that in the case of an fatal error full
board reset is required.
The enetc_hw.h header was imporoted from Linux. It is dual licensed.
Submitted by: Kornel Duleba <mindal@semihalf.com>
Obtained from: Semihalf
Sponsored by: Alstom Group
Differential Revision: https://reviews.freebsd.org/D30729
Provide common MDIO code for two LS1028 ENETC controllers -
an external one found on the PCI bus and internal one found in ENETC.
Submitted by: Lukasz Hajec <lha@semihalf.com>
Reviewed by: manu
Obtained from: Semihalf
Sponsored by: Alstom Group