freebsd-src/sbin/startslip/startslip.1
1994-12-04 12:26:01 +00:00

119 lines
3.8 KiB
Groff

.\" Copyright (c) 1990, 1991, 1993
.\" The Regents of the University of California. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\" 3. All advertising materials mentioning features or use of this software
.\" must display the following acknowledgement:
.\" This product includes software developed by the University of
.\" California, Berkeley and its contributors.
.\" 4. Neither the name of the University nor the names of its contributors
.\" may be used to endorse or promote products derived from this software
.\" without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" @(#)startslip.1 8.1 (Berkeley) 6/5/93
.\"
.Dd June 5, 1993
.Dt STARTSLIP 1
.Os BSD 4.4
.Sh NAME
.Nm startslip
.Nd dial up and login to a slip server
.Sh SYNOPSIS
.Nm startslip
.Op Fl d
.Op Fl b Ar speed
.Op Fl s Ar string
.Op Fl A Ar annexname
.Op Fl F Ar flowcontrol
.Op Fl U Ar upscript
.Op Fl D Ar downscript
.Ar device user passwd
.Sh DESCRIPTION
.Nm Startslip
opens the specified
.Ar device .
.Pp
Once carrier is asserted
.Nm startslip
attempts to login as the specified
.Ar user
with the given
.Ar password .
If successful, it puts the device into the slip line discipline.
If carrier drops and a
.Dv SIGHUP
is sent to
.Nm startslip ,
it closes the device and attempts to repeat the dialup and login sequence.
.Pp
Available options:
.Bl -tag -width Ar
.It Fl d
.Nm Startslip
prints out debugging information about what it is trying to do.
.It Fl b Ar speed
Determines the baud rate used for
.Ar device .
.It Fl s Ar string
The optional
.Ar string
is written to
.Ar device .
For a dialup modem,
the string is used to specify a dial sequence.
.It Fl A Ar annexname
.Nm Startslip
assumes it is connecting to a Xylogics Annex box and engages in an
appropriate dialog using the
.Ar user
and
.Ar passwd
arguments.
The
.Ar annexname
argument is a string that is used to match against the Annex prompt
to determine when a connection has been established.
.It Fl F Ar flowcontrol
Determines the type of flow control used on
.Ar device .
Choices for
.Ar flowcontrol
are
``none'' for no flow control (the default),
``hw'' for hardware RTS/CTS flow control and
``sw'' for software XON/XOFF flow control.
.It Fl U Ar upscript
Specifies a script to run when a SLIP interface becomes connected. This may
contain ifconfig, route, and other appropriate commands. The arguments that
are passed to the script are "slX up".
.It Fl D Ar downscript
Specifies a script to run when a SLIP connection goes away. The arguments that
are passed to the script are "slX down".
.El
.Sh SEE ALSO
.Xr sliplogin 8
.Sh HISTORY
The
.Nm startslip
appeared in
.Bx 4.4 .